Diesel Generating Sets
Durable, reliable and efficient, IMPAC generators are built strong to meet the demanding needs of mission critical industries like telecom, aviation and hospitals.
IMPAC Diesel Generators have been designed and manufactured specifically to cater to industries that demand high quality and reliability. The grueling conditions in which IMPAC Generators are deployed range from -30C to +55C, and up to 4,000 meters above sea level and are perfectly suitable where power uptime is essential.
Technical Specifications
| IMPAC Model | Engine Model | Alternator Model | kVA (Prime) | kW (Prime) | kVA (Stand-by) | kW (Stand-by) |
|---|---|---|---|---|---|---|
| QC2R9PL | 403D-11G | LSA40VS2 | 9 | 7.20 | 9.50 | 7.60 |
| QC2R13L | 403D-15G | LSA40VS2 | 13 | 10.40 | 14.00 | 11.20 |
| QC2R17L | 404D-22G | LSA404S | 17 | 13.60 | 18.00 | 14.40 |
| QC2R20L | 404D-22TG | LSA404S | 20 | 16.00 | 21.50 | 17.20 |
| QC2R27L | 1103A-33G | LSA42.2M7 | 27 | 21.60 | 30.00 | 24.00 |
| QC2R30L | 1103A-33G | LSA42.2M7 | 30 | 24.00 | 33.00 | 26.40 |
| QC2R35L | 1103A-33TG1 | LSA43.2S25 | 35 | 28.00 | 39.00 | 31.20 |
| QC2R40L | 1103A-33TG2 | LSA43.2M45 | 40 | 32.00 | 44.00 | 35.20 |
| QC2R60L | 1103A-33TG2 | LSA43.2M45 | 60 | 48.00 | 63.00 | 50.40 |
| QC2R80L | 1104A-44TG2 | LSA44.2VS45 | 80 | 64.00 | 88.00 | 70.40 |
| QC2R100L | 1104A-44TAG2 | LSA44.2VS45 | 100 | 80.00 | 110.00 | 88.00 |
| Cylinder | Engine Power kW/Net |
Compression Ratio |
Bore & Stroke (mm) |
Displacement (Ltrs) |
Lube Oil Capacity (Ltrs) |
Coolant Capacity (Ltrs) |
Fuel Consumption at 50% (Ltrs/hr) |
Fuel Consumption at 100% (Ltrs/hr) |
Air Efficiency (%) |
|---|---|---|---|---|---|---|---|---|---|
| 3 | 8.40 | 23:1 | 77 x 81 | 1.13 | 4.90 | 5.20 | 1.70 | 3.00 | 82.70 |
| 3 | 12.00 | 22.5:1 | 84 x 90 | 1.50 | 6.00 | 6.98 | 2.00 | 3.60 | 87.50 |
| 4 | 18.40 | 23.3:1 | 84 x 100 | 2.20 | 6.98 | 6.98 | 2.90 | 5.40 | 87.90 |
| 4 | 18.40 | 23.3:1 | 84 x 100 | 2.20 | 6.98 | 6.98 | 2.90 | 5.40 | 87.10 |
| 3 | 27.70 | 19.25:1 | 105 x 127 | 3.30 | 7.90 | 10.20 | 3.90 | 7.10 | 88.90 |
| 3 | 27.70 | 19.25:1 | 105 x 127 | 3.30 | 7.90 | 10.20 | 3.90 | 7.10 | 89.00 |
| 3 | 41.30 | 17.25:1 | 105 x 127 | 3.30 | 7.90 | 10.20 | 5.70 | 10.70 | 87.90 |
| 3 | 41.30 | 17.25:1 | 105 x 127 | 3.30 | 7.90 | 10.20 | 5.70 | 10.70 | 89.00 |
| 3 | 53.80 | 17.25:1 | 105 x 127 | 3.30 | 10.00 | 12.00 | 7.70 | 13.70 | 89.00 |
| 4 | 71.90 | 17.25:1 | 105 x 127 | 4.40 | 13.20 | 16.00 | 9.20 | 18.00 | 90.50 |
| 4 | 89.00 | 18.2:1 | 105 x 127 | 4.41 | 8.00 | 12.60 | 11.20 | 22.60 | 90.80 |
| 3 | 8.40 | 23:1 | 77 x 81 | 1.13 | 4.90 | 5.20 | 1.70 | 3.00 | 82.70 |
Frequently Asked Questions
kW (kilowatts) measures actual power output, while kVA (kilovolt-amperes) measures apparent power, including power lost due to inefficiency. The ratio of kW to kVA is called the power factor.
Standby: Used for emergency power during utility outages, not designed for continuous use.
Continuous: Can run indefinitely at a constant load.
Prime: Suitable for continuous operation but with variable loads up to a defined maximum.
Yes, many generators can be reconfigured or equipped with additional components to adjust their output voltage.
An Automatic Transfer Switch (ATS) automatically switches the power source from the utility to the generator during a power outage, ensuring continuous power supply.
Some generators are capable of operating at either 60 Hz or 50 Hz. Whether a specific model can be converted depends on its design; consult the manufacturer for details.
Paralleling is possible if both generators have compatible control systems and specifications. It's advisable to check with the manufacturer for compatibility.
Calculate the total power requirements by adding up the wattage of all devices that need power. Consider both running and starting power needs, especially for equipment with motors or compressors, to determine the appropriate generator size.